Products
Your Position : Home - Products - Tank samplerProducts
Under Can Sampler LTCY- X type

Operating principle and features
LTCY-X type based on the floating power pulling, the reams connected to “X” components and which make the sampling mouth liquid level change with 1/6ΙΟ, 1/2, 1/6 proportion.
For the “X” components are all the same and the sampling mouth with liquid level is rather precision which can guarantee the 2 meters above precision can be 100%.
The floating plate pulling should be less than 30Kg without horizontal pulling which can make sure the plate is safe and the installation is rather simple.
.jpg)
Technology index
Suitable tank: floating cover tank
Suitable medium: all mediums
Sampling precision: the total difference is less than 1.5 %
Minimum sampling: 2 meters
Suitable temperature: -40°C~95°C(inside tank)
Working life: 8 years